平面钢制闸门以机构简单合理,强度高、止水性能好、承压能力大、密封性能好、生产周期短,使用维护方便等特点广泛适用于各种排水工程,作或局部封闭过水孔口,以调节上、下游水位和流量。那么其到底该如何选型呢?远超机电小编以表格的形式为您梳理如下。
一、平面钢制闸门选型表
| 孔 口 宽 mm | 孔 口 高 度 mm |
| 1000 | 1500 | 2000 | 2500 | 3000 | 3500 | 4000 | 4500 | 5000 | 5500 |
| 1000 | ● | ● |
|
|
|
|
|
|
|
|
| 1500 | ● | ● | ● |
|
|
|
|
|
|
|
| 2000 | ● | ● | ● |
|
|
|
|
|
|
|
| 2500 | ● | ● | ● | ● |
|
|
|
|
|
|
| 3000 |
|
| ● | ● |
|
|
|
|
|
|
| 3500 |
|
| ● | ● |
|
|
|
|
|
|
| 4000 |
|
| ● | ● |
|
|
|
|
|
|
| 孔 口 宽 mm | 孔 口 高 度 mm |
| 2500 | 3000 | 3500 | 4000 | 4500 | 5000 | 5500 | 6000 | 7000 | 8000 |
| 4500 |
|
| ● | ● |
| ● | ● | ● |
|
|
| 5000 |
|
| ● | ● | ● | ● | ● | ● |
|
|
| 6000 |
|
|
|
| ● |
| ● |
|
|
|
| 7000 |
|
|
|
| ● | ● | ● | ● | ● |
|
| 8000 |
|
|
|
| ● | ● | ● | ● | ● | ● |
| 9000 |
|
|
|
| ● | ● | ● | ● | ● | ● |
| 10000 |
|
|
|
|
| ● | ● | ● | ● | ● |
| 11000-15000 |
|
|
|
| ● |
| ● |
| ● |
|
二、平面钢制闸门选型还应考虑的技术特性
1、强度与刚度
1.1、材料选择:制造平面钢闸门所用的钢材应符合图样要求,其性能应符合**有关标准的规定,并附有出厂合格证。例如,面板、腹板、翼板等主要构件通常采用Q235钢。
1.2、结构设计:设计应闸门在zui大水头下一般不易发生弯曲变形,所有结合部分和滑动表面都应是机械加工面。对于启闭机螺杆及驱动装置,其拉伸、压缩和剪切强度的安全系数应大于5。
2、止水性能
2.1、止水材料:止水橡胶的物理机械性能应符合《水利水电工程钢闸门制造安装及验收规范》的规定,其硬度应符合施工图纸要求。例如,采用橡胶止水时,止水橡胶应预留不少于3mm的压缩量。
2.2、止水装置布置:止水装置宜设置在门叶上,顶止水、底止水、两侧止水和中间止水应具有连续性和严密性。止水座板面的平面度应为0.000 02hB′,且不超过0.3,止水面的表面粗糙度应为1.6。
3、耐磨耐蚀性
3.1、防腐要求:设计应考虑工作介质,合理选择防腐型式,明确防腐要求。例如,闸门的金属结构表面可采用防腐涂层或镀层材料进行保护。
3.2、材料耐蚀性:对于长期在水中工作的闸门,其材料应具有的耐蚀性。例如,闸门的螺杆可采用不锈钢材料。
4、尺寸与公差
4.1、构件尺寸偏差:单个构件制作的允许偏差应符合相关标准的规定。例如,构件宽度b的允许偏差为±2mm,腹板的倾斜度a应为1/150。
4.2、止水部件尺寸:止水宽度B′的允许偏差为±3mm,顶、底止水间距h′的允许偏差为±2mm。
5、启闭性能
5.1、启闭力:启闭力的计算应包括闭门力、持住力和启门力,其中摩擦阻力安全系数可采用1.5。
5.2、启闭设备:启闭机的功率和启闭力应满足闸门启闭的要求。例如,某些闸门的启闭机功率为0.75kw,启闭力为40KN。
因此,在平面钢制闸门选型时,应综合考虑以上技术性能问题,并根据具体的工程需求和环境条件,选择合适的平面钢制闸门型号和规格,以有助于其在实际应用中的安全、可靠和经济性。